thermocouple
37 photos tagged thermocouple, from 1 member of Flickr Commons.
Where were these photos tagged?
None of these photos are geotagged.
Related tags
Tags that often appear on the same photos:
- vibrationtesting
- shakertable
- rohrfactory
- modallab
- february
- march
- 1997
- adelclamp
- accelerometer
- greentape
- wiringharnesstest
- heatlamp
- milledaluminum
- anchornuts
- pressuresensor
- acousticabsorber
- environmentaltest
- straingauges
- materialsresearch
- thermal
- johnwilson
- lstock
- vibrationanalysis
- shielding
Members using this tag
Photos
Photos tagged thermocouple:
Loading photos…
Recent uploads
The last upload was December 2025.
26_0049754 Rohr Collection Image from SDASM Archives uploaded December 2025
26_0016296 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016294 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016295 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016292 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016293 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016291 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016285 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016284 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016283 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016278 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016277 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016187 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016186 Rohr Collection Image from SDASM Archives uploaded April 2025
26_0016184 Rohr Collection Image from SDASM Archives uploaded April 2025
Conversations
Here’s a selection of the conversations happening on these photos:
26_0016283 Rohr Collection Image
from SDASM Archives
-
Chuck Walla said:
This could be rotated 90 degrees clockwise.
26_0015025 Rohr Collection Image
from SDASM Archives
-
Chuck Walla said:
This is likely to be the plant in Washington state.
Warning signs say "HOT" confirming this is a heat process.
There is a cart with manufactured parts. The cart is fitted with thermocouples which are wired into the Quality Assurance console at right. The parts get rolled into the chamber and heated to some specification, The Quality Assurance console surveils local tempeatures to check that heat is applied to meet a specification. It looks like 3 sets of paper charts are created: one in the Quality Assurabce cart and two others in the chamber's control console (left).
The Quality Assurance console may also contain a data logger which would print thermocouple temperatures on what looks like an adding machine tape. Like the strip charts, they prove the parts got the heating in their manufacturing specification.
26_0016184 Rohr Collection Image
from SDASM Archives
-
Chuck Walla said:
Guess: they're troubleshooting a noise or coupling problem between the braided wiring when the product is vibrating?